Nittan Europe, a UK-based renowned manufacturer of conventional and addressable fire detection products and systems, is proud to have its Evolution analog addressable fire detectors installed into the NHS Nightingale Hospital Bristol.

NHS Nightingale Hospital Bristol

Built in less than three weeks at the University of West of England Frenchay campus, NHS Nightingale Hospital Bristol has the capacity to provide up to 300 intensive care beds for coronavirus patients, if local services need them. 

The new facility is one of seven Nightingale hospitals to be set up around the country as part of a massive NHS effort to respond to the COVID-19 health emergency.

Evolution analogue addressable fire detectors

Nittan’s Evolution analog addressable fire detectors have been incorporated into Ramtech Electronics’ WES wireless firm alarm system, which is designed to provide a simple, fast and secure method of communicating fire and medical emergencies in the complex environmental conditions of construction sites.

While WES has been designed to provide temporary protection on construction sites, its ease of use, reliability and quality made it ideal for use in the temporary Nightingale Hospital. 

Wireless fire alarm systems

Wireless fire alarm systems are ideal for temporary sites as they don’t require specialist trades to set up

Wireless fire alarm systems are ideal for temporary sites as they don’t require specialist trades to set up, and any number of call points can be deployed in minutes and linked wirelessly to cover large or small sites.

The signal passes through all commonly found materials including steel, concrete and stone.

Evolution EVC-DP dual optical detectors

Nittan Evolution EVC-DP dual optical detectors are incorporated into the WES system. These award-winning detectors feature dual optical technology to reduce false alarms caused by non-combustion products such as steam, dust and aerosols. 

Unlike other conventional detectors on the market that claim to distinguish between smoke and non-combustion products, the EVC-DP effectively measures the actual particle size in the chamber via its combined IR and blue LED technology. 

No false alarms

As steam and dust are much larger particles than smoke, the detector won’t cause false alarms. This makes the EVC-DP detector ideally suited to use in hospitals, hotels and other areas of multiple occupancy which are prone to steam and dust.

The WES wireless fire alarm system featuring the Nittan detectors has been installed into the communal and welfare areas of NHS Nightingale Hospital Bristol.

Download PDF version Download PDF version

In case you missed it

VIKING Expands Service Network In Northern Norway
VIKING Expands Service Network In Northern Norway

VIKING Life-Saving Equipment is expanding its network of owned service stations in Norway by acquiring the safety department of Tromsø-based company Lindrup Martinsen AS. T...

The Impact Of Cybersecurity On The Fire Service
The Impact Of Cybersecurity On The Fire Service

The integration of technology into the fire service has significantly enhanced operations, but it has also introduced new vulnerabilities. Cybersecurity has become a concern for fi...

Dräger Donates AirBoss SCBA For Fire Angels' Marathon
Dräger Donates AirBoss SCBA For Fire Angels' Marathon

Dräger is donating self-contained breathing apparatus (SCBA) and helmets to the ‘Fire Angels’, two female firefighters who will be attempting seven marathons, in...

vfd