Download PDF version

One of the biggest topics within the fire industry in the last few years has been cancer prevention and awareness. Everyone knows the importance of this, but what is something that can be targeted immediately, to prevent preliminary exposure after being on scene?  

NFPA 1851 specifies the recommended actions for the cleaning and drying of turnout gear. It defines three types of cleaning: preliminary exposure reduction, advanced, and specialized, which regard hazmat contaminants. Let’s cover the requirements and benefits of preliminary exposure reduction and advanced cleaning to begin.  

Preliminary Exposure Reduction 

Preliminary Exposure Reduction should occur after every incident where soiling has occurred

Preliminary Exposure Reduction should occur after every incident where soiling has occurred. This can be fire, smoke, or attached debris of any kind.

This first step will mitigate airborne particulate up to 85% and reduce cross-contamination. 

Here are some tips to follow: 

  • Remain on self-contained breathing apparatus (SCBA) air.
  • Deploy wet mitigation by gently rinsing the exterior of ensembles and ensemble elements by using low-pressure and low-volume flow water.
  • Do not use chlorine bleach.
  • Use cool or warm water that does not exceed 105°F (40°C).
  • Use mild detergent.
  • Brush any debris with a gentle bristle brush.
  • Rinse gear until the water runs clear.
  • Doff ensemble and ensemble elements, isolate, and place inside a bag for transport back to the station.

Advanced cleaning 

If the department has washing machines and is a manufactured or verified ISP-trained organization, they can take on Advanced Cleaning. Gear Wash is rigorously tested to ensure that the cleaning methods meet a standard clean.

This is why the NFPA requires advanced cleanings at least twice a year, but they recommend sending the gear in more to increase the longevity of what they wear. It is imperative that the department sends in gear as often as needed, as this will reduce any further exposure to risky carcinogens. 

Advanced cleaning is their bread and butter. Now that everyone can see the main differences between these two processes, they can be educated and well-informed when making decisions for the department and their personal health and safety. 

Download PDF version Download PDF version

In case you missed it

Stay Focused On Fire Performance Guidance, Says AEI Cables
Stay Focused On Fire Performance Guidance, Says AEI Cables

Cables pioneer - AEI Cables is warning the supply chain not to forget the important implications in the guidance on Category 3 Control fire performance cables among the range of ne...

One Key To Firefighter Wellness: A Good Night’s Sleep
One Key To Firefighter Wellness: A Good Night’s Sleep

For firefighters, sleep is a valuable commodity. But duty often calls no matter what the clock says.   Sleep deprivation Indeed, sleep deprivation is a common challenge...

Ajax Systems Has Achieved Membership Of The Fire Industry Association (FIA) In The United Kingdom
Ajax Systems Has Achieved Membership Of The Fire Industry Association (FIA) In The United Kingdom

Ajax Systems has officially joined the Fire Industry Association (FIA). The FIA is the largest fire protection trade association in Europe, and its membership provides access to a...

vfd