Download PDF version

Testing by CCCA finds high failure rate in electrical performance of imported category 6 copper patch cords.

The Communications Cable and Connectivity Association (CCCA) announced that it recently completed large-scale, electrical performance testing of Category 6 copper patch cords. Test results show an 85% failure rate in patch cords produced offshore by companies who are largely unknown in North America. A second, large sample set of Category 6 copper patch cords produced by multiple, well-recognized manufacturers was also tested and showed 0% failure rate. Copper patch cords are typically used to connect network devices for signal routing (i.e. wall outlets, patch panels, switches, routers).

CCCA's patch cord testing program follows the communications cable testing program conducted in 2008 and 2009, which uncovered a serious fire safety hazard with non-compliant copper data communications cable imported into North America.

To assure statistically meaningful results, CCCA tested a total of 499 samples from 16 brand names of Category 6 patch cords at a UL (Underwriters Laboratories) audited test lab. 322 of 379 patch cords made by offshore manufacturers, not generally known in North America, failed to meet minimum industry electrical performance requirements as specified in TIA 568-C.2. 78% of the failing samples failed by a margin of 3dB or more and 45% of the failing samples failed by margin of 6dB or more. Because noise is measured on a logarithmic scale, a 3dB failure indicates a noise level that is twice as high as the allowable standards and failures of this magnitude could contribute to significant network problems.

Included in the testing pool were 120 Category 6 copper patch cords from well-known manufacturers in North America. All had a 100% pass rate.

None of the failing products was identified as using independent, third party testing laboratories to verify quality. Patch cord testing and verification programs are available from leading independent testing agencies and generally provide a level of quality assurance to buyers.

Frank Peri, CCCA's Executive Director said: "Once again, we see disturbing test results that seem to fit the pattern uncovered with our testing of offshore bulk data communications cable. The overwhelming failure rate of these offshore patch cords is very unsettling, suggesting that the manufacturers exporting these products are likely aware they are selling faulty products. The lack of third party verification with lesser known brands should put all users on alert to be sure they are getting the performance they expect and are paying for."

CCCA emphasizes that many of its members are well recognized global companies with offshore manufacturing facilities and business operations. The quality issues and failure to comply with industry standards are not necessarily regional in nature, but rather the result of the use of low quality components, poor assembly methods, and poor quality controls, which can improve profit margin for the manufacturer.

Download PDF version Download PDF version

In case you missed it

Stay Focused On Fire Performance Guidance, Says AEI Cables
Stay Focused On Fire Performance Guidance, Says AEI Cables

Cables pioneer - AEI Cables is warning the supply chain not to forget the important implications in the guidance on Category 3 Control fire performance cables among the range of ne...

One Key To Firefighter Wellness: A Good Night’s Sleep
One Key To Firefighter Wellness: A Good Night’s Sleep

For firefighters, sleep is a valuable commodity. But duty often calls no matter what the clock says.   Sleep deprivation Indeed, sleep deprivation is a common challenge...

Ajax Systems Has Achieved Membership Of The Fire Industry Association (FIA) In The United Kingdom
Ajax Systems Has Achieved Membership Of The Fire Industry Association (FIA) In The United Kingdom

Ajax Systems has officially joined the Fire Industry Association (FIA). The FIA is the largest fire protection trade association in Europe, and its membership provides access to a...

vfd