Download PDF version
Hochiki Europe’s intrinsically safe devices are incapable of releasing sufficient electrical or thermal energy

The CHQ-ISM is designed for use in the ‘safe’ area of a hazardous area fire detection system

Hochiki Europe, the leading manufacturer of innovative life safety solutions, has announced the latest addition to its expanding range of intrinsically safe compatible devices – the CHQ-ISM sounder module.

Hochiki Europe’s intrinsically safe devices are incapable of releasing sufficient electrical or thermal energy to cause the ignition of a specific hazardous atmospheric mixture in its most easily ignitable concentration. This is achieved by limiting the amount of power available to the electrical equipment in the hazardous area to a level below that where ignition is possible. The low power levels also mean that there is no shock hazard due to excess thermal energy and arcing.

With a similar look and feel as the standard modules in the range, the CHQ-ISM is designed for use in the ‘safe’ area of a hazardous area fire detection system and, therefore, does not require specialised certification. It allows any third party sounders and beacons installed in the ‘hazardous’ area to be controlled and monitored by an analogue addressable control panel that is configured around Hochiki Europe’s innovative Enhanced Systems Protocol (ESP). The unit is wired either directly to the panel via the conventional sounder circuits – receiving its 24V power supply from the panel – or via a CHQ-DSC sounder controller module connected to the loop, where it requires a separate 24V power supply.

In both instances a suitable intrinsically safe barrier must be used. Hochiki Europe supplies two recommended barriers for this purpose – the MTL5561 galvanic isolator or the MTL7787+ Zener barrier. The module also provides line monitoring for open or short circuits on the wiring connected to both the ‘safe’ and ‘hazardous’ areas.

Paul Adams, Hochiki Europe’s deputy marketing manager, commented, ‘The protection of those in hazardous environments can be greatly enhanced by the correct specification, installation and maintenance of a suitable fire detection system. The CHQ-ISM sounder module is the latest addition to our already successful intrinsically safe compatible product range, which is designed to ensure the optimum levels of safety for people and property in potentially dangerous surroundings.’

Download PDF version Download PDF version

In case you missed it

Stay Focused On Fire Performance Guidance, Says AEI Cables
Stay Focused On Fire Performance Guidance, Says AEI Cables

Cables pioneer - AEI Cables is warning the supply chain not to forget the important implications in the guidance on Category 3 Control fire performance cables among the range of ne...

One Key To Firefighter Wellness: A Good Night’s Sleep
One Key To Firefighter Wellness: A Good Night’s Sleep

For firefighters, sleep is a valuable commodity. But duty often calls no matter what the clock says.   Sleep deprivation Indeed, sleep deprivation is a common challenge...

Ajax Systems Has Achieved Membership Of The Fire Industry Association (FIA) In The United Kingdom
Ajax Systems Has Achieved Membership Of The Fire Industry Association (FIA) In The United Kingdom

Ajax Systems has officially joined the Fire Industry Association (FIA). The FIA is the largest fire protection trade association in Europe, and its membership provides access to a...

vfd