Warringtonfire, a pioneer in fire testing, inspection and certification services, has completed the second in a series of three studies at the request of the Flemish Government, that focus on fire safety in residential care buildings.

When asked about the goals of the second study, also called the VIPA2 study, Pieter Poppe - project manager, stated, "We wanted to identify the effectiveness of smoke control measures using five large-scale fire tests and additional CFD-simulations (CFD: Computational Fluid Dynamics) as part of the evacuation strategy for non-self-reliant occupants of a residential care building."

VIPA2 study

The VIPA2 study led to new ways of considering fire safety for more vulnerable members of society, such as citizens who reside within care buildings.

Since common areas within these buildings can currently include combustible materials (e.g. kitchens, sofas, etc.), a possible fire hazard is inherent in these evacuation routes. This risk is currently not considered within the concept of the current (Belgian) fire safety regulations.

Applications of a smoke control system

VIPA2 study has demonstrated the effectiveness of different kinds of applications of a smoke control system"

"The VIPA2 study has scientifically demonstrated the effectiveness of different kinds of applications of a smoke control system in a residential care building. This kind of smoke control system is not only limited to residential care buildings but can also be applied to all types of structures with similar geometry.”

Such application is not mentioned in any normative document related to Smoke and Heat Exhaust Ventilation systems (SHEV-system) and is therefore very innovative." This research, completed by Warringtonfire has informed a further third study, the VIPA3 study.

Assessment framework

Pieter Poppe, Head of the Consultancy Department of the Institute for Fire Safety (ISIB), said, "In the VIPA3 study, an assessment framework has been developed where minimum fire safety measures are determined as part of the evacuation strategy (i.e. immediate evacuation or Defend in Place) in case of non-self-reliant occupants of a residential care building.”

These fire safety measures can be active (e.g. residential smoke control system, fire screen, automatic extinguishing) or passive safety measures (e.g. fire resistant door, smoke control door, fire resistant damper).”

safe and secure regulations

The effectiveness of the applied fire safety measures has been demonstrated through large-scale fire tests and additional CFD simulations (CFD: Computational Fluid Dynamics) as described in the VIPA1 and VIPA2 studies."

 The three studies will act as crucial stepping stones in creating a safer and more secure future for non-self-reliant individuals, by potentially guiding future regulations.

In case you missed it

WAGNER's Fire Protection Solutions At BUILDINX 2025
WAGNER's Fire Protection Solutions At BUILDINX 2025

WAGNER Group GmbH will be presenting pioneering solutions for fire protection in modern logistics properties at BUILDINX 2025 in Dortmund from November 18 to 20, 2025. The foc...

Spare A Minute For Maintenance
Spare A Minute For Maintenance

With new fire safety regulations around the corner and a renewed focus on responsible persons and coordination, Karen Trigg of Allegion UK discusses the significance of fire door h...

Fire-Dex Unveils Fire Investigation PPE For Safety
Fire-Dex Unveils Fire Investigation PPE For Safety

Fire investigators have long worked in a gray area of protection where full structural turnouts are overkill, but single-layer garments may not cover every single hazard they encou...

vfd