The fire alarm control equipment from UK manufacturer, Advanced, has been installed at the core of a wireless fire detection system protecting Leuchie House in East Lothian on the Scottish Borders.

As part of an upgrade to the existing radio fire system at the classical Georgian mansion house in North Berwick which operates as a respite center for people with multiple sclerosis, an Advanced 4-loop MxPro 5 fire panel has been installed alongside the latest EMS wireless FireCell equipment.

Fire detection systems

The MxPro 5 was selected to protect the five-storey, 18th century building and its residents, thanks to its compatibility with EMS FireCell XP detection – one of the most advanced cable-free fire detection systems available on the market.

Responsible for the design, installation, commissioning and maintenance of the fire system at Leuchie House is Galashiels-based Safe Services, who required a solution capable of delivering seamless protection whilst keeping disruption to the fabric of the building at a minimum. As a listed building, retaining a radio fire system was agreed to be the most suitable form of protection to safeguard the features of this period property. Installing cabling would have been intrusive to the décor and difficult and costly to achieve in the more inaccessible areas of the site.

Multiprotocol fire system

The MxPro 5 fire panel was the obvious choice for installation at the core of this wireless fire detection system

Graeme Millar, Fire Systems Technical Engineer at Safe Services, said: “Having worked with Advanced products for many years, we were confident that we could rely on its solutions to perform as required. Now that Advanced supports EMS wireless FireCell detection, the MxPro 5 fire panel was the obvious choice for installation at the core of this wireless fire detection system, effortlessly ensuring protection across all five levels of the building.”

The MxPro 5 is the unbeatable multiprotocol fire system. Approved to EN54-2, 4 and 13, it offers four protocols, Apollo, Argus, Hochiki and Nittan and a completely open installer network that benefits from free training and technical support. Panels can be used in single-loop, single-panel format or easily configured into high-speed networks of up to 200-panels covering huge areas.

Protecting historic buildings

MxPro 5 panels are backwards compatible with existing MxPro 4 networks and include a host of features including AlarmCalm for complete false alarm management and reduction. Neil Parkin, Sales Manager for the North, said: “Advanced offers a wide range of solutions to help our customers overcome the common problems encountered when protecting historic buildings.”

The fire protection now in place at Leuchie House makes great use of the versatility Advanced offers"

The fire protection now in place at Leuchie House makes great use of the versatility Advanced offers – minimizing aesthetic impact, supporting a diverse range of detection options and supporting the fast and safe evacuation of buildings.” Advanced, owned by FTSE 100 company Halma PLC, protects a wide range of prestigious and high-profile sites across the globe – from London’s Shard to Abu Dhabi International Airport and the Hong Kong-Zhuhai-Macau Bridge.

Intelligent fire systems

Halma is a global group of life-saving technology companies with a clear purpose to grow a safer, cleaner, healthier future for everyone, every day. Advanced is a pioneer in the development and manufacture of intelligent fire systems.

Advanced’s reputation for performance, quality and ease of use see its products specified in locations around the world, from single-panel installations to large, multi-site networks. Advanced’s products include complete fire detection systems, multiprotocol fire panels, extinguishing control, fire paging and false alarm management and reduction systems.

Share with LinkedIn Share with Twitter Share with Facebook Share with Facebook
Download PDF version Download PDF version

In case you missed it

Preventing Restaurant Fires Requires Maintenance And Technology
Preventing Restaurant Fires Requires Maintenance And Technology

Many restaurants around the world are suffering from loss of income due to the COVID-19 pandemic. The situation has made fire prevention a lower priority. Fire authorities should work with restaurant owners and associations to address this issue and offer guidelines and training to increase awareness in the community. Restaurant fires account for about 6% of all non-residential building fires reported to fire departments each year, according to the National Fire Incident Reporting System (NFIRS). These fires resulted in an average of less than one fatality per 1,000 fires, 11 injuries per 1,000 fires, and US$ 23,000 in loss per fire. Cooking, major cause of restaurant fires As one might expect, cooking is by far the leading cause of restaurant fires, accounting for 64% of restaurant fires, according to NFIRS. Heating and electrical malfunction each accounted for an additional 7% of incidents. All other causes, including unintentional, careless actions (4%), appliances (4%), other heat (3%) and several other categories at less than 3%, each accounted for the remaining 23% of restaurant fires, according to the National Fire Incident Reporting System. According to the National Fire Protection Association (NFPA) and the U.S. Fire Administration (USFA), the top five causes of fires in restaurants are cooking equipment, with 61%, followed by electrical fires, heating equipment, smoking materials and intentional. Kitchen exhaust systems under high fire risk equipment At the top of the list of fire risks, related to cooking equipment, is a kitchen’s exhaust systems At the top of the list of fire risks, related to cooking equipment, is a kitchen’s exhaust systems, which are a common cause of fire, when they are not properly maintained. They build up grease, until a point where the hot smoke and steam that goes through the ventilation ignites that grease and causes fires. Also, grease traps should be properly emptied and cleaned or they will catch fire. Also, related to cooking, other common causes of restaurant fires are gas leaks or malfunctions due to poor maintenance. Not as common, but also a culprit of fire losses are fires caused by inadequate use of deep fryers or large cooking pans, and faulty cooking equipment such as pressure cookers. Detectors and automatic suppression systems Ivan Paredes, Latin American Head of Product Marketing for Fire Detection at Bosch Security and Safety Systems, lists the following technologies used to prevent and/or minimize restaurant fires: Automatic suppression systems built into stoves and oven hoods. Foam that reacts with the grease and CO2 extinguishing are the most common. Heat and smoke detectors located near the cooking area. UL 268 7th edition-approved smoke detectors can be installed inside kitchens and should not give unwanted alarms. Flammable gas leak detectors and automatic fail-safe valves to avoid gas leaks. Importance of regular maintenance of systems “The main challenge in fire prevention in restaurants is awareness and local regulation compliance,” said Ivan Paredes, adding “Restaurant owners should schedule regular maintenance of systems, proper cleaning of areas where grease and oil build up or are stored, and guarantee proper ventilation of the kitchen at all times.” He adds, “Restaurant staff also should be properly trained in fire prevention as well as the use of fire extinguishers and the systems installed (automatic suppression, gas leak detection, etc.) and regular housekeeping helps avoid flammable materials igniting near fire sources such as stoves and ovens.”

PAMS Software Promotes Accountability Of Fire Service Responders
PAMS Software Promotes Accountability Of Fire Service Responders

The fire service has always struggled with maintaining accurate accountability of personnel who are responding or operating in emergencies. Lack of firefighter accountability is often cited as a contributing factor in Line of Duty Deaths (LODD). Compounding the accountability challenge are volunteer responders who can be coming from anywhere, with some going to the station and others going direct. The existing accountability tools and processes were unreliable and failed when needed the most. Need for reliable and accurate system As a firefighter and Incident Commander, Justin Brundage witnessed firsthand the data gaps of the tools and processes commonly used. A reliable and accurate system was needed in the fire service to avoid unnecessary risk to responses and responders. The intuitive process fits within an existing response workflow and provides an end-to-end solution  Seeking to address the problem, Brundage co-founded Incident Management Technology, whose Personnel Accountability Management System (PAMS) software is a solution for maintaining accurate and reliable firefighter accountability. The intuitive process fits within an existing response workflow and provides an end-to-end solution for firefighter accountability. The software was developed to solve operational gaps in emergency response and to help departments operate more effectively and safely. Real-time operations With the PAMS system, all personnel can see the available, deployed, and responding staff and resources in real-time on a mobile app or web browser. Responding apparatus are also viewable in real-time, including all the personnel on the apparatus. At an incident, the software tools simplify the accurate tracking and management of all personnel on the scene and enable a shared common picture of the who, what, and where of all responders at all times. PAMS gives department members and officers the information they need in real-time to optimize their responses. “We do this by sharing availability and response information throughout the department on a smartphone app,” says Brundage. Operational safety In addition to the improvement in operational safety that agencies get from PAMS, the software also improves response. “When all responders can see the other responders’ destinations and estimated times of arrival (ETAs) they can adapt and optimize the response efficiency by responding where they are needed most and not duplicating unnecessarily,” says Brundage.  PAMS software functions as an electronic equivalent to tag-based systems, which are ineffective, cumbersome, and error-prone. The key difference is that, by being electronic, the “accountability” information is viewable to anyone connected to the agency in real-time, regardless of location. Computer-aided dispatch (CAD) The software manages the responder throughout the lifecycle of the emergency response New incidents are sent to the responder mobile app automatically from computer-aided dispatch (CAD). Responders mark up if they are responding, and the system calculates and shares each responder's destination and ETA. The software manages the responder throughout the lifecycle of the emergency response. The entire department can see who is responding, who is assigned to each responding apparatus, who is operating at the incident, and where they are operating. Because this is an electronic process managing the personnel, is much easier with timers on task activities, and a simple and quick participatory action research (PAR) process. Fits in emergency workflow PAMS software is designed to fit into the existing workflow of an emergency response. “As responders ourselves we understand the burden of adding more operational requirements to the already chaotic moments of response and incident mitigation,” says Brundage. PAMS was built to work effectively on the equipment that is in many cases already deployed and installed in the response apparatus. The mobile app is available for iOS and Android and is used by the personnel responders, and then the web app is browser-based and can run on a browser window on tablets, mobile computing devices (MDCs), and laptops. Affordable, But has a lack of awareness In rolling out the product, awareness has proven to be a challenge for Incident Management Technology. “As a startup company most agencies that would benefit from the system aren’t aware that a solution like this even exists,” says Brundage. The system is expanding features and functionality to maximize incident response effectiveness The system is expanding features, functionality, and integrations rapidly intending to build an affordable solution for all fire departments to minimize their operational risks and to maximize their incident response effectiveness. Benefits of the software “We are currently having success with organic growth and the network effect,” says Brundage. “Our current customers are showing the system and validating the benefits to other agencies local to them, and we are increasing our awareness that way every day.” He adds, “We love doing web demos and talking to fire and EMS departments. Most fire departments have the same operational challenges, and the feedback we receive from customers and prospects is what we use to drive our next phase of software development.”

Using State-Of-The-Art Technology To Prevent And Put Out Wind Turbine Fires
Using State-Of-The-Art Technology To Prevent And Put Out Wind Turbine Fires

As more and more countries in Europe and North America commit to net zero, a key strategy is replacing old fossil fuel-driven forms of power generation and replacing them with renewable energy, such as wind turbines and solar panels. The wind industry has seen a particular boom, with tens of thousands of new turbines installed every year across the globe. However, like any other heavy machinery, wind turbines can catch fire due to mechanical or electrical failures. These fires can have impacts beyond the turbine if there is secondary fire spread to surrounding lands, resulting in potentially catastrophic loss. Without this technology in place, a single fire could cost $7-8 million and cause substantial downtime. The time is now for the industry to use all available technology to prevent these incidents and reduce the risk of fires spilling into the environment. How do wind turbine fires start? Wind turbine fires can catch fire due to external causes, such as lightning strikes, or internal causes, such as mechanical or electrical failure resulting in sparks or heat in the nacelle. Most nacelle fires start at one of three points of ignition – converter and capacitor cabinets, the nacelle brake, or the transformer. Nacelle brakes are used to stop the turbine’s blades from spinning in an emergency.  Converter and capacitor cabinets and transformers are necessary for the turbine to generate power and transform it into a voltage that can be exported to the grid. An electrical fault at either location can produce arc flashes or sparks, which can ignite nearby Class A combustibles, like cables, plastics, or fiberglass. Nacelle brakes are used to stop the turbine’s blades from spinning in an emergency. The brakes can cause turbine fires, albeit due to sparks from mechanical stress and friction rather than electrical failure. While some turbines have been designed with safer, electrical brakes, mechanical brake systems are often used as a backup in the event of power or control failure. These ignition points are all necessary for the safe generation of electricity from the wind, and cannot simply be designed out. As such, wind farm owners and operators must be ready to deal with fires when they spark. Why are wind turbine fires hard to fight? Modern wind turbines often exceed 250 feet in height, while most ground-based firefighting can only reach up to 100 feet. A team sent up-tower to manually fight the fire would constitute a major health and safety risk, as turbines have limited space and escape routes – putting employees not only in direct contact with fire but at risk of being in the turbine if it collapses. As such, when turbines catch fire, they are often left to burn out, with firefighters’ efforts focused on preventing the spread and clearing the area as fiery debris falls. This results in irreparable damage to the turbine, necessitating its replacement. What is the cost of a wind turbine fire? The cost of replacing a burned-out wind turbine depends on a number of factors. First and foremost is the size and initial cost of the turbine. Turbines with more than 3MW of rated capacity can cost between $3-10 million to install during development. Replacement turbines can often cost even more, as manufacturers are likely to charge more for individual, one-off installations. Another key loss is business interruption, or how long the turbine was offline – and therefore not generating revenue. The average loss due to a turbine fire was estimated by insurance company GCube to be $4.5 million in 2015. As turbines have grown larger and therefore more expensive to replace with greater losses in revenue, we expect a fire to cost anywhere between $7-8 million for new models. How can turbine owners and manufacturers manage fire risk? Firetrace’s system is designed with flexible Heat Detection Tubing, which ruptures in response to extreme heat or open flame Turbine manufacturers are already taking steps to “design out” fire risk in turbines. For example, lightning protection systems on turbine blades safely re-direct the surge of electricity away from cables, while condition monitoring systems can identify whether a component is overheating and likely to catch fire. In order to put out any turbine fires that do start at their source, turbine owners and manufacturers can install automatic fire suppression systems at common points of ignition. Firetrace’s system is designed with flexible Heat Detection Tubing, which ruptures in response to extreme heat or open flame, releasing a clean suppression agent precisely at the source of the fire before it can spread. Wind farm owners who have taken a more proactive approach to manage risk via fire suppression systems have been able to snuff out fires before they can spread throughout the turbine or into the environment. By investing in the latest technology for fire suppression, owners and operators have avoided the worst-case scenario, saving millions in operating costs.

vfd